Computational Fluid Dynamics Modeling of Proximal Landing Zones for Thoracic Endovascular Aortic Repair in the Bovine Arch Variant
Annals of Vascular Surgery, ISSN: 0890-5096, Vol: 69, Page: 413-417
2020
- 4Citations
- 13Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations4
- Citation Indexes4
- Captures13
- Readers13
- 13
Article Description
To assess the endograft displacement forces (DF), which quantify the forces exerted by the pulsatile blood flow on the vessel wall and transmitted on the terminal fixation site of the endograft after its deployment in proximal landing zones (PLZs) of the bovine aortic arch variant. Thirty healthy aortic computed tomographic angiographies of subjects with bovine arch configuration (10 per type of arch, I–III) were selected for the purpose of the study. A 3-dimensional model of the aortic arch lumen was reconstructed. Computational fluid dynamics modeling was then used to compute DF magnitude and orientation (i.e., x, y, and z axes) in PLZs of each case. DF values were normalized to the corresponding aortic wall area to estimate equivalent surface traction (EST). DF were highest in zone 0, consistently with the greater surface area. DF in zone 3 were much greater than in zone 2 because of a 3-fold greater upward component ( z axis) ( P < 0.001), being therefore mainly oriented orthogonally to the aortic blood flow and to the vessel longitudinal axis in that zone. EST progressively increased from zone 0 toward more distal PLZs, with EST in zone 3 being much greater than that in zone 2 ( P < 0.001). The same pattern was observed after stratification by type of arch. The bovine arch is associated with a consistent fluid dynamic pattern, which identifies in zone 3 an unfavorable biomechanical environment for endograft deployment.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0890509620304313; http://dx.doi.org/10.1016/j.avsg.2020.05.024; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85087203417&origin=inward; http://www.ncbi.nlm.nih.gov/pubmed/32479874; https://linkinghub.elsevier.com/retrieve/pii/S0890509620304313; https://dx.doi.org/10.1016/j.avsg.2020.05.024