Ultrasensitive determination of mercury by ICP-OES coupled with a vapor generation approach based on solution cathode glow discharge
Chinese Chemical Letters, ISSN: 1001-8417, Vol: 33, Issue: 5, Page: 2692-2696
2022
- 27Citations
- 7Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations27
- Citation Indexes27
- 27
- CrossRef1
- Captures7
- Readers7
Article Description
We herein proposed a sample introduction technique based on solution cathode glow discharge (SCGD) of a portable design for inductively coupled plasma-optical emission spectrometry (ICP-OES) and its application in sensitive determination of mercury. The products from SCGD containing mercury vapor, were transported by an Ar flow to ICP spectrometer for detection. A gas liquid separator (GLS) and a dryer were used to condense and remove most of the accompanying moisture, which greatly improved both the stability and sensitivity of the signal. The detection limit (DL) acquired by this developed method was 0.22 µg/L (194.1 nm), which was nearly 82 times lower than that obtained by pneumatic nebulization (PN). The relative standard deviation (RSD) was 1.4% ( n = 14) for a 50 µg/L standard. Blank solution (HNO 3, pH 1) can effectively elute mercury residue. Its accuracy and practicality were also demonstrated by the determination of GBW10029 (fish) certified reference material, shrimp, crawfish, soil and human hair samples. The results showed good consistency with the certified values and the values obtained using inductively coupled plasma−mass spectrometry.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S1001841721008342; http://dx.doi.org/10.1016/j.cclet.2021.09.107; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85121902180&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S1001841721008342; https://dx.doi.org/10.1016/j.cclet.2021.09.107; http://sciencechina.cn/gw.jsp?action=cited_outline.jsp&type=1&id=7222413&internal_id=7222413&from=elsevier
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know