Ratiometric fluorescence detection of sulfide ions based on lanthanide coordination polymer using guanosine diphosphate as ligand
Colloids and Surfaces B: Biointerfaces, ISSN: 0927-7765, Vol: 204, Page: 111796
2021
- 20Citations
- 6Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations20
- Citation Indexes20
- 20
- CrossRef6
- Captures6
- Readers6
Article Description
The efficiency of energy transfer from guanine nucleotide to terbium ion (Tb 3+ ) is affected by the phosphate group significantly. Compared with the biomolecules 5′-GMP (guanosine monophosphate), guanosine diphosphate (GDP) exhibits better sensitize ability to Tb 3+ ions luminescence. Assisted with the carboxycoumarin ligand, we synthesized a more stable optical Coumarin@GDP-Tb polymer with the characteristic emission peaks located on 440 nm and 545 nm in this work. The Coumarin@GDP-Tb polymer is not only rich in metal binding sites, but also maintains a moderate ionic binding force, which helps metal ions to bind or leave it easily. Experiment result shows that Coumarin@GDP-Tb polymer has the appropriate binding force for Fe 2+ ions, which can be destroyed by sulfur ions (S 2− ) as the formation of FeS precipitation. Based on this, Coumarin@GDP-Tb was designed as the ratio fluorescence probe for sulfur ions detection, where the fluorescence at 545 nm can be selectively quenched by Fe 2+ ions, while that at 440 nm was unaffected, in the presence of S 2− ions, the quenched fluorescence can be recovered remarkably. With the increasing S 2− ions from 0.1–45 μM, the ratio of fluorescence intensity at 545 nm to 440 nm (F 545 /F 440 ) is linear to S 2− concentration, and the detection limit of S 2− was calculated to be 0.073 μM. Contrast to those fluorescence probes with single wavelength emission, Coumarin@GDP-Tb displays a comparable sensitivity, the introduced self-adjust wavelength improved the detection accuracy efficiently. The above 98.1 % recovery rates of S 2− ions in the actual water sample demonstrated the practicability of Coumarin@GDP-Tb fluorescence probe.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S092777652100240X; http://dx.doi.org/10.1016/j.colsurfb.2021.111796; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85104920694&origin=inward; http://www.ncbi.nlm.nih.gov/pubmed/33933879; https://linkinghub.elsevier.com/retrieve/pii/S092777652100240X; https://dx.doi.org/10.1016/j.colsurfb.2021.111796
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know