Thermal-hydraulic performance of a plate heat exchanger with grooved copper foam
Case Studies in Thermal Engineering, ISSN: 2214-157X, Vol: 51, Page: 103525
2023
- 1Citations
- 7Captures
- 1Mentions
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Most Recent News
King Mongkut's University of Technology North Bangkok Researchers Release New Data on Thermal Engineering (Thermal-hydraulic performance of a plate heat exchanger with grooved copper foam)
2023 NOV 06 (NewsRx) -- By a News Reporter-Staff News Editor at Engineering Daily News -- Researchers detail new data in thermal engineering. According to
Article Description
This study proposes a plate heat exchanger (PHE) partially filled with metal foam having checkered pattern grooves. The study presents new experimental data obtained from PHE with grooved copper foam that elucidates the effect of mass flux, copper foam groove width, and pore density on the heat transfer coefficient (HTC) and pressure drop ( ΔP ). The testing is conducted with a water mass flux ranging from 120 to 320 kg/m 2 s, a groove width ranging from 2 to 6 mm, and a pore density of 30 pores per inch (PPI) and 50 PPI. The results demonstrate that HTC and ΔP increase as the copper foam groove width is reduced. Considering the impact of copper foam groove width on the filling rate, the HTC ratio increases significantly at a filling rate between 50 and 75%. Furthermore, an increase in pore density enhances HTC and ΔP. The plate heat exchanger inserted with copper foam (PHE_CF) provides the optimum thermal-hydraulic performance (TP). However, at a low Reynolds number, the results show that TP of PHE with grooved copper foam with a groove width of 2 mm is similar to PHE_CF. New correlations are also proposed to predict ΔP and HTC in the practical applications.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S2214157X23008316; http://dx.doi.org/10.1016/j.csite.2023.103525; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85173580917&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S2214157X23008316; https://dx.doi.org/10.1016/j.csite.2023.103525