Electrochemical pH sensor based on a hydrogen-storage palladium electrode with Teflon covering to increase stability
Electrochemistry Communications, ISSN: 1388-2481, Vol: 101, Page: 73-77
2019
- 5Citations
- 32Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
A pH sensor was fabricated using a modified hydrogen-storage palladium electrode. The Pd electrode stores H 2 generated electrochemically at suitable potentials. After the Pd electrode had become coated with palladium hydride (PdH x ), the resting potential of the modified Pd electrode responded to changes in the pH with a near-Nernstian response of −56.2 ± 0.2 mV pH − 1 in the range from pH 1 to pH 13. Although such Pd electrodes are usually unstable due to the release of H 2, their stability could be dramatically increased by covering with a Teflon tube. The Pd electrode can be easily regenerated by electrolysis. As H 2 gas is spontaneously released from the modified Pd electrode, the partial pressure of H 2 gas on the surface of the Pd electrode is almost constant (H 2 gas is almost saturated in the vicinity of the electrode). Accordingly, the potential is assumed to be determined by the pH value of the aqueous solution based on the redox potential of the H 2 |H + couple. When the pH value of the solution is almost constant, the modified Pd electrode can act as a reference electrode without any leakage of the inner electrolyte that occurs with Ag|AgCl|sat. KCl electrodes.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S138824811930061X; http://dx.doi.org/10.1016/j.elecom.2019.03.003; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85062439207&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S138824811930061X; https://dx.doi.org/10.1016/j.elecom.2019.03.003