Long-term stability of screen-printed pseudo-reference electrodes for electrochemical biosensors
Electrochimica Acta, ISSN: 0013-4686, Vol: 287, Page: 29-36
2018
- 25Citations
- 63Captures
- 1Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Most Recent News
PET-Based Microfluidic Sensor to Assess Blood Glucose Levels
Real-time monitoring can also significantly reduce the risk of diabetes complications, enhance blood glucose control, and improve the overall quality of life.
Article Description
Pseudo reference electrodes forms an essential part of electrochemical transducers, where they are used to maintain a reference potential for the system. Yet, little is known about their long-term stability, and any drift may cause undesired changes in the sensor signal. This paper investigates the stability of the reference potential of five material systems of screen-printed reference electrodes. Their potential was continuously monitored for a duration of 40 days in a phosphate buffered solution, and any signal changes were corroborated with EDX elemental analyses, SEM micrographs and cyclic voltammetry. The electrodes were considered to be stable as long as they remained within 30 mV of their initial potential throughout the study. It was found that Ag/AgCl electrodes with a 3:1 atomic ratio kept a stable reference potential (±2.2 mV), whereas Ag/AgCl electrodes with a 9:1 atomic ratio, despite showing good overall constancy of ±3.2 mV, seemed to statistically lose stability towards the end of the 40 day trial due to AgCl depletion through dissolution. The daily potential drift for the respective Ag/AgCl electrodes were −0.2 mV (3:1 ratio) and −0.1 mV (9:1 ratio), suggesting a proportionality between the amount of dissociated AgCl close to the electrode surface and the initial AgCl loading. Electrodes consisting of only Ag showed tendencies towards a mixed potential contribution, which reduced the long-term stability (±24.2 mV) as well as the longevity span (2 days). Ag/Pd electrodes proved to be more unstable (±29.7 mV), with an average lifetime of around 3.5 days. Pt had the greatest potential instability (±59.8 mV), rendering its average lifetime to less than a day. It was shown that electrodes which deviates from the Ag/AgCl equilibrium had the greatest potential variation with time.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0013468618318218; http://dx.doi.org/10.1016/j.electacta.2018.08.045; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85052131895&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0013468618318218; https://dul.usage.elsevier.com/doi/; https://api.elsevier.com/content/article/PII:S0013468618318218?httpAccept=text/xml; https://api.elsevier.com/content/article/PII:S0013468618318218?httpAccept=text/plain; https://dx.doi.org/10.1016/j.electacta.2018.08.045