Experimental study on operation characteristics of a novel refrigeration system using phase change material
Energy and Buildings, ISSN: 0378-7788, Vol: 150, Page: 516-526
2017
- 22Citations
- 53Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
A refrigeration system using phase change material (PCM) with six operating modes is proposed to reduce the cooling energy use of energy-demanding spaces such as data centers and telecommunication base stations. PCM is used to store the cold of outdoor air (OA) and/or that produced by vapor compression refrigeration (VCR) at night, and to release the stored energy for indoor cooling during the daytime. Real-time space cooling and cold charging by VCR can be accomplished simultaneously. Free cooling from OA can provide significant energy saving for space conditioning. A prototype system using a commercially available PCM was developed and tested to investigate the system performance and operation characteristics. The temperatures of air, water and refrigerant were measured along with the refrigerant pressure. The study calculates and analyzes the refrigerating capacity, cooling capacity, cold storage rate, supplied cold, stored cold, and the coefficient of performance (COP) upon the measurements. Experimental results indicate that the proposed refrigeration system can perform the requested tasks in a stable manner. The paper further compares the operating performances with the cold from OA and from VCR. It is found that under the outdoor temperature of 15 °C, OA appears to be more energy-efficient than VCR when the stored cold is less than 5.8 MJ, but it takes more time to charge the cold.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0378778817302773; http://dx.doi.org/10.1016/j.enbuild.2017.05.069; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85021064529&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0378778817302773; https://api.elsevier.com/content/article/PII:S0378778817302773?httpAccept=text/xml; https://api.elsevier.com/content/article/PII:S0378778817302773?httpAccept=text/plain; https://dx.doi.org/10.1016/j.enbuild.2017.05.069