Optimization of daylight in atrium in underground commercial spaces: A case study in Chongqing, China
Energy and Buildings, ISSN: 0378-7788, Vol: 256, Page: 111739
2022
- 22Citations
- 35Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Facing urban problems such as rapid urbanization, air pollution, heatwaves, and urban flooding, the underground space, as a significant urban composition, has demonstrated the unique potential. However, the properties of the lighting environment in underground spaces require the consumption of large amounts of energy. An optimal design strategy for natural daylighting in underground commercial spaces with high density, high usage, and high illumination demand can effectively achieve energy savings. In this study, the most common natural daylighting structure, the atrium, was selected. And the orthogonal analysis was used to simulate the lighting environment generated by four influencing factors (shape, number, profile inclination, and skylight aspect ratio) of underground commercial spaces. For an atrium space of two floors, the results show that the case of 1–3 square-shaped atriums, a profile inclination of 5°-10°, and a skylight aspect ratio of 1:6 comprised a suitable combination that can significantly reduce the electricity consumption. Different combinations of the four influencing factors resulted in different energy savings rates, and the highest energy savings rate was 1.2–1.3 times higher than the lowest. This study can be a valuable insight into the energy-saving design of the light environment in underground space.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0378778821010239; http://dx.doi.org/10.1016/j.enbuild.2021.111739; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85120978640&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0378778821010239; https://dx.doi.org/10.1016/j.enbuild.2021.111739