Performance evaluation of multifunctional windows for commercial buildings under hot-humid climatic environments
Energy and Buildings, ISSN: 0378-7788, Vol: 303, Page: 113816
2024
- 3Citations
- 8Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
The Multifunctional Window (MFW) is a novel solution for solar radiation optimal utilization in commercial buildings. The present work aims to evaluate the performance of the Multifunctional Window consisting of multi-glazed window, liquid-absorbing filter, and traditional photovoltaic for use in near-zero-energy commercial buildings. Fulfilling this goal, a simulation model using CFD code was developed to predict the effect of design parameters such as absorbing filter liquid types (Pure water-polyethylene glycol–water/Ag Nanofluid), liquid filter thickness (2–10 mm), and air gap thickness (5–15 mm) on window performance characteristics and building energy savings under hot and humid climates. Results showed that the water/Ag Nanofluid (NF) minimize the PV surface temperatures by up to 3.2 °C and increase the power saving by about 6.4–9.8 % in comparison to other tested fluids i.e., NF is the best liquid filter from viewpoint of total power saving. As the thickness of the liquid filter increases, the transmitted indoor visible light radiation reduces by 43.6% and the average room load decreases by 47.6%. The average interior window surface temperature and room load of MFW are 4.1% and 60.7% lower than Window with PV only, respectively. The proposed MFW has the highest energy performance compared to typically adopted glazing systems.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0378778823010460; http://dx.doi.org/10.1016/j.enbuild.2023.113816; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85183342065&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0378778823010460; https://dx.doi.org/10.1016/j.enbuild.2023.113816
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know