Highly selective and sensitive fluorometric probe for Cd 2+ ions based on 4-(quinolin-2-ylmethylene)aminoanisole Schiff base
Inorganica Chimica Acta, ISSN: 0020-1693, Vol: 536, Page: 120884
2022
- 14Citations
- 10Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Herein, we report a reversible and easy assembled fluorometric probe (4-(quinolin-2-ylmethylene)aminoanisole, QMAA ) for the highly selective and sensitive detection of cadmium ion (Cd 2+ ) in DMF solution with PBS buffer (0.01 M, pH = 7.30). The strong fluorescence response of QMAA to Cd 2+ along with a bright blue fluorescence was mainly ascribed to the formation of the complex QMAA–CdCl2. The results show that the complexation can inhibit the C N isomerisation and photo–induced electron transfer (PET), and further lead to the occurrence of chelation fluorescence enhancement. The 1:1 stoichiometry of the complex between QMAA and cadmium ion was studied by fluorescence titration, Job’s plot analysis, 1 H NMR, FT–IR, and ESI–MS data, and was further confirmed by the single crystal structure of the complex QMAA–CdCl2. Density functional theory (DFT) calculations have verified the mechanism of fluorescence enhancement. In addition, the limit of detection of QMAA for Cd 2+ was as low as 0.1547 µM (at 10 –7 M level), which was lower than the acceptable limit of Cd 2+ level in drinking water defined by World Health Organization. The analog experiments about nature contamination of Cd 2+ in real samples were finished.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0020169322000962; http://dx.doi.org/10.1016/j.ica.2022.120884; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85125288219&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0020169322000962; https://dx.doi.org/10.1016/j.ica.2022.120884
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know