Comprehensive CFD analysis of base pressure control using quarter ribs in sudden expansion duct at sonic Mach numbers
International Journal of Thermofluids, ISSN: 2666-2027, Vol: 24, Page: 100908
2024
- 6Citations
- 7Captures
- 1Mentions
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Most Recent News
Research Data from University Sains Malaysia Update Understanding of Thermofluids (Comprehensive CFD analysis of base pressure control using quarter ribs in sudden expansion duct at sonic Mach numbers)
2024 DEC 30 (NewsRx) -- By a News Reporter-Staff News Editor at Tech Daily News -- Research findings on thermofluids are discussed in a new
Article Description
This study aims to assess the effect of rib size, shape, and location in a suddenly expanded flow at sonic Mach number. Flow from a converging nozzle is exhausted into a larger area of duct diameter of 18 mm. The geometric parameters considered are the area ratio, duct length, rib radius, and inertia parameters, which are considered the level of expansion at critical Mach number. In the present study, duct lengths were from 1D to 6D, rib radii considered were 1 mm to 3 mm, and rib locations were 0.5D, 1D, 1.5D, 2D, and 3D. Results show that when the ribs are placed near the reattachment point with a 3 mm radius, they are efficient and capable of reducing the suction in the recirculation zone and the base pressure, which was lower than the ambient pressure in the absence of ribs, is assorted larger than the back pressure. If the requirement is to equate the pressure at the base to ambient pressure, then a 2 mm radius is the right choice. Furthermore, the 1 mm rib cannot reduce the suction in the base region, and base pressure remains sub-atmospheric for the entire range of rib locations, as well as the NPRs of the present study. When the orientation of the ribs is changed, and the flow interacts with the flat surface instead of the curved surface, there is a marginal change in the flow pattern, and there is no significant change in the base pressure values.
Bibliographic Details
Elsevier BV
Provide Feedback