Gas refractive index sensor with an integrated prism and a microlens array
Optik, ISSN: 0030-4026, Vol: 279, Page: 170747
2023
- 2Citations
- 2Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
A novel sensor for measuring the refractive index of gas is realized by the integration of a prism and a micro-lens array. The proposed sensor is constructed in a single optical path setup and relies on neither a spectrometer nor other spectrum-sensing devices. In the proposed sensor, the gas is injected into the chamber equipped with the prism, and the wavefront of the exit probe beam is decomposed by the microlens array to realize multi-focalization. The developed sensor is utilized to measure the refractive indexes of the air and nitrogen. The refractive index of nitrogen using the proposed sensor is in agreement with data reported previously. By considering twice the standard deviation, a precision of 4.70 × 10 –6 RIU is achieved for the refractive index measurement of nitrogen
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0030402623002437; http://dx.doi.org/10.1016/j.ijleo.2023.170747; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85149440782&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0030402623002437; https://dx.doi.org/10.1016/j.ijleo.2023.170747
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know