Performance analysis of four-stage thermoelectric cooler for focal plane infrared detectors
International Journal of Refrigeration, ISSN: 0140-7007, Vol: 165, Page: 290-302
2024
- 1Citations
- 1Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
A cooler provides a low-temperature working environment for refrigerated infrared detection chips and is an indispensable component in infrared detectors that ensures their smooth operation. In this paper, a thermodynamic model of a heat-pipe-type four-stage thermoelectric cooler with a large temperature difference applied to a focal plane infrared detector is constructed. The heat leakage of the detector is calculated using the model. The performance indexes of the coordination performance coefficient and module utilization coefficient are used to unify the cooling capacity and economic performance of the device. The impression of the working current, heat pipe parameters, and cross-sectional area of the thermoelectric leg on the performance of cooler are analyzed. A Pareto optimal solution is obtained using an NSGA-II algorithm and TOPSIS decision. A low cooling temperature is obtained using a multistage thermoelectric cooler to achieve a large cooling temperature difference. When the working current is 5.65 A and the cross-sectional area is 4.5 mm 2, the maximum cooling temperature difference reaches 110.6 °C, and the lowest cooling temperature reaches -83.6 °C. When the working temperature of the detector is -60 °C, the current and cross-sectional area corresponding to the optimal solution of cooling capacity-COP-power consumption are 1.51 A and 2.74 mm 2, respectively.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0140700724002147; http://dx.doi.org/10.1016/j.ijrefrig.2024.06.011; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85197215854&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0140700724002147; https://dx.doi.org/10.1016/j.ijrefrig.2024.06.011
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know