Coronary Artery Occlusion Detection Using 3-Lead ECG System Suitable for Credit Card-Size Personal Device Integration

JACC: Advances, ISSN: 2772-963X, Vol: 2, Issue: 6, Page: 100454
2023
  • 5
    Citations
  • 0
    Usage
  • 12
    Captures
  • 66
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

  • Citations
    5
  • Captures
    12
  • Mentions
    66
    • News Mentions
      66
      • News
        66

Most Recent News

HeartBeam announces US FDA clearance for at-home, high-fidelity heart monitoring technology

HeartBeam has announced that the US Food and Drug Administration (FDA) has granted 510(k) clearance of the HeartBeam system for comprehensive arrhythmia assessment. A press

Article Description

Early coronary occlusion detection by portable personal device with limited number of electrocardiographic (ECG) leads might shorten symptom-to-balloon time in acute coronary syndromes. The purpose of this study was to compare the accuracy of coronary occlusion detection using vectorcardgiographic analysis of a near-orthogonal 3-lead ECG configuration suitable for credit card-size personal device integration with automated and human 12 lead ECG interpretation. The 12-lead ECGs with 3 additional leads (“abc”) using 2 arm and 2 left parasternal electrodes were recorded in 66 patients undergoing percutaneous coronary intervention prior to (“baseline”, n = 66), immediately before (“preinflation”, n = 66), and after 90-second balloon coronary occlusion (“inflation”, n = 120). Performance of computer-measured ST-segment shift on vectorcardgiographic loops constructed from “abc” and 12 leads, standard 12-lead ECG, and consensus human interpretation in coronary occlusion detection were compared in “comparative” and “spot” modes (with/without reference to “baseline”) using areas under ROC curves (AUC), reliability, and sensitivity/specificity analysis. Comparative “abc”-derived ST-segment shift was similar to two 12-lead methods (vector/traditional) in detecting balloon coronary occlusion (AUC = 0.95, 0.96, and 0.97, respectively, P  = NS). Spot “abc” and 12-lead measurements (AUC = 0.72, 0.77, 0.68, respectively, P  = NS) demonstrated poorer performance ( P  < 0.01 vs comparative measurements). Reliability analysis demonstrated comparative automated measurements in “good” agreement with reference (preinflation/inflation), while comparative human interpretation was in “moderate” range. Spot automated and human reading showed “poor” agreement. Vectorcardiographic ST-segment analysis using baseline comparison of 3-lead ECG system suitable for credit card-size personal device integration is similar to established 12-lead ECG methods in detecting balloon coronary occlusion.

Bibliographic Details

Shvilkin, Alexei; Vukajlović, Dejan; Bojović, Boško P; Hadžievski, Ljupčo R; Vajdic, Branislav; Atanasoski, Vladimir A; Miletić, Marjan N; Zimetbaum, Peter J; Gibson, C Michael; Vukčević, Vladan

Elsevier BV

Medicine; Dentistry

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know