Two-dimensional paper chromatography-based fluorescent immunosensor for detecting acute myocardial infarction markers
Journal of Chromatography B, ISSN: 1570-0232, Vol: 967, Page: 139-146
2014
- 29Citations
- 28Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations29
- Citation Indexes29
- 29
- CrossRef22
- Captures28
- Readers28
- 28
Article Description
A novel washing scheme following antigen–antibody reactions with analyte was used during construction of a fluorescent immunosensor to resolve the background problem in the lateral flow assay with human serum. An immuno-membrane strip was devised to simultaneously measure cardiac troponin I (cTnI), creatinine kinase-MB isoform (CK-MB), and myoglobin to diagnose acute myocardial infarction. This strip was then installed within a cartridge containing a built-in washing solution tank, which was used to supply the solution across the signal generation pad of the strip after the immune reactions. Such cross-flow washing was initiated by onset-signaling from the internal control and began to run automatically upon sample addition. Under optimal conditions, the immunosensor displayed a stably suppressed background baseline, enabling us to attain a low detection limit for cTnI (0.05 ng/mL) as well as favorable reproducibility for repetitive measurements (relative standard deviation <10%). No interference was observed among the different complex formations at the respective analyte sites, and no artifacts were caused by sample matrices. We tested the performance relationship with the Pathfast reference system for positive serum samples (36 for cTnI, 58 for CK-MB, and 17 for myoglobin), and the correlation coefficients were >0.98. This result suggests that the new immunosensor system based on two-dimensional chromatography can be used for clinical testing
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S1570023214004917; http://dx.doi.org/10.1016/j.jchromb.2014.07.026; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84905369180&origin=inward; http://www.ncbi.nlm.nih.gov/pubmed/25089959; https://linkinghub.elsevier.com/retrieve/pii/S1570023214004917; https://dx.doi.org/10.1016/j.jchromb.2014.07.026