Axial compressive behavior and design of high-strength square concrete-filled steel tube short columns with embedded GFRP tubes
Journal of Constructional Steel Research, ISSN: 0143-974X, Vol: 207, Page: 107955
2023
- 9Citations
- 12Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
This paper proposed a hybrid column by embedding glass fiber-reinforced polymer (GFRP) tube into high-strength square concrete-filled steel tube (CFT), named as high-strength square steel-concrete-GFRP concrete (SCFC) column. A total of 13 high-strength square SCFC short columns were tested. The test parameters included diameter and thickness of GFRP tube, width and thickness of steel tube, yield stress of steel, and compressive strength of concrete. Results showed that high-strength square SCFC short columns exhibited post-yield strengthening behavior and stable residual strength. The axial strength, confining effect, and ductility were improved because of the embedded GFRP tube. Detailed finite element models were developed and benchmarked to investigate the strength contribution of each component and conduct parametric studies. It was shown that: (i) the concrete infill and the steel tube contributed >90% to the overall compressive strength and (ii) the strength improvement by embedding GFRP tube was closely related to the section size ratio, confinement ratio of the GFRP tube, and confinement ratio of the steel tube. Evaluation of the current equations showed that they were not accurate enough to estimate the axial compressive strength of high-strength square SCFC short columns. New equations were then proposed.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0143974X23001827; http://dx.doi.org/10.1016/j.jcsr.2023.107955; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85152605251&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0143974X23001827; https://dx.doi.org/10.1016/j.jcsr.2023.107955
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know