Amperometric glucose sensing with polyaniline/poly(acrylic acid) composite film bearing covalently-immobilized glucose oxidase: A novel method combining enzymatic glucose oxidation and cathodic O 2 reduction
Journal of Electroanalytical Chemistry, ISSN: 1572-6657, Vol: 712, Page: 119-123
2014
- 30Citations
- 26Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
The film of polyaniline/poly(acrylic acid) composite was prepared by electrochemical polymerization of aniline in the presence of poly(acrylic acid). An enzyme electrode was fabricated with the composite film by immobilizing glucose oxidase covalently on its surface. Amperometric glucose sensing was carried out with the enzyme electrode by monitoring O 2 consumption accompanying enzymatic glucose oxidation. Prior to the glucose sensing, the electrochemical properties of the composite film were investigated with respect to cathodic O 2 reduction. On the basis of the result, the glucose sensing was conducted at applied potential of −0.3 V vs. SCE in a phosphate buffer solution of pH 7.0. The current response was found to increase linearly with an increase in glucose concentration up to 1.1 mM. The sensitivity was 29.9 ± 5.1 μA mM −1 cm −2 with the detection limit of 0.06 ± 0.02 mM ( S / N = 3). The response was not affected by such coexisting electroactive compounds as ascorbic acid and acetaminophen.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S1572665713005067; http://dx.doi.org/10.1016/j.jelechem.2013.11.009; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84889687594&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S1572665713005067; https://dx.doi.org/10.1016/j.jelechem.2013.11.009
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know