Determination and speciation of selenium in water samples collected from Muğla (Turkey) province by hydride generation atomic absorption spectrometry
Journal of the Indian Chemical Society, ISSN: 0019-4522, Vol: 99, Issue: 7, Page: 100511
2022
- 4Citations
- 14Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
In this work, determination of selenium in various water samples was done by using hydride generation atomic absorption spectrometry. The most appropriate values of HCl concentration, NaBH 4 concentration, NaOH concentration, flow rate of argon and flow rate of waste solution were determined. The optimum concentration of the HCl, NaBH 4 and NaOH solutions were found to be 7.0 mol L −1, 1.0% and 0.75%, respectively. The optimum flow rate of Ar gas and waste solution were also found to be 100.9 mL min −1 and 4.0 mL min −1, respectively. Values of LOD and LOQ were calculated separately for total Se and Se(IV). LOD and LOQ values were calculated 0.56 μg L −1, 1.87 μg L −1 for total Se and 0.72 μg L −1, 2.40 μg L −1 for Se(IV), respectively. The precision was evaluated by relative standard deviation (RSD%) was found to be 3.5% for total Se and 3.1% for Se(IV) (n = 11). A standard reference material (NIST 1643e) was used in order to check the accuracy of the proposed method. There was a good agreement between certified and found values for standard reference material. The method was applied to the analysis of total Se and Se(IV) concentrations in tap water samples collected from the various regions of Muğla. Proposed method showed spike recovery ranges from 92% to 116% in water samples.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S001945222200173X; http://dx.doi.org/10.1016/j.jics.2022.100511; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85129485056&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S001945222200173X; https://dx.doi.org/10.1016/j.jics.2022.100511
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know