Impact of bridge heterology on functional parameters of ELISA for 17α-methyltestosterone
Journal of Immunological Methods, ISSN: 0022-1759, Vol: 522, Page: 113572
2023
- 2Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures2
- Readers2
Article Description
In this study, we have developed bridge heterologous ELISA for the detection of 17α- Methyltestosterone by incorporating aromatic spacers between 17α-Methyltestosterone-3-Carboxymethyloxime and Horseradish peroxidase label through N-hydroxysuccinimide mediated carbodiimide reaction method. The immunogen 17α-Methyltestosterone-3-Carboxymethyloxime-Bovine serum albumin used to generate the antibody was also prepared by the N-hydroxysuccinimide mediated carbodiimide reaction without using any spacer. We have studied the impact of bridge/aromatic spacers on functional parameters i.e. sensitivity, affinity and ED 50 of the bridge heterologous assay and compared it with homologous assay. The five combinations of bridge heterologous assay using 17α-Methyl testosterone-3-CMO-BSA antiserum and 17α-MT-3-CMO-4,4’-Diaminodiphenyl sulphide-HRP, 17α MT-3-CMO-4,4’-Oxydianiline-HRP, 17α-MT-3-CMO-Benzidine-HRP, 17α- MT-3-CMO-p-Phenylenediamine-HRP and 17α-MT-3-CMO-Dapson-HRP enzyme conjugates were evaluated. Out of these five combinations, the combination 17α-MT-3-CMO-BSA with 17α-MT-3-CMO-Benzidine-HRP showed the best results. Sensitivity, affinity and ED 50 were improved and found to be 0.02 ng/mL, 0.086 × 10 −8 L/mol and 2.95 ng/mL than homologous assay where Sensitivity, affinity and ED 50 were 0.11 ng/mL, 0.02 × 10 −8 L/mol and 5.78 ng/mL respectively. The cross-reactivity for this bridge heterologous assay combination was seen with only 4 steroids (6-hydrotestosterone- 6%, Testosterone-5.14%, Danazol-0.9% and Nandrolone-0.85%) instead of eight steroids (6-hydrotestosterone-43.75%, Testosterone-38.3%, Danazol-25.14%, Androstenediol-19.16%, Nandrolone-19%, Metandienone-5%, Androstenedione-3.52%, and 17α dimethyltestosterone-2%) as in homologous assay out of 59 structurally related steroids. Thus, the results of this study conclude that the incorporation of aromatic spacer (bridge) in enzyme conjugate has a crucial role in improving sensitivity, specificity, ED 50 and affinity of the developed assay. The assay was then studied for parameters such as recovery (97.4%–108.6%), precision (Inter and Intra-assay coefficient of variation <10%), correlation coefficient (R 2 = 0.96) by comparing with the commercial kit and validated by measuring levels of 17α- methyltestosterone in rat serum after administering them.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0022175923001540; http://dx.doi.org/10.1016/j.jim.2023.113572; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85172882744&origin=inward; http://www.ncbi.nlm.nih.gov/pubmed/37774776; https://linkinghub.elsevier.com/retrieve/pii/S0022175923001540; https://dx.doi.org/10.1016/j.jim.2023.113572