Fast-cure ionogel electrolytes with improved ion transport kinetics at room temperature
Journal of Power Sources, ISSN: 0378-7753, Vol: 406, Page: 141-150
2018
- 1Citations
- 9Captures
Metric Options: Counts3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Fast-cure 1-ethyl-3-methylimidazolium trifluoromethanesulfonate-based ionogels have been realised for the first time. The influence of curing temperature on the structure of ionogels and their performance as the electrolyte for electric double-layer capacitors (EDLCs) has been investigated. Hybrid ionogels were synthesised via a non-hydrolytic sol-gel route and were fully gelled post heat-treating at 125, 150, 175 and 200 °C for 60 min with minimal shrinkage. Charge-transfer resistance (a rate-limiting parameter in cell kinetics during charge/discharge cycles) was reduced by ∼80% by increasing the heat-treatment temperature; this was partially attributed to the interlocking effect facilitated by high curing temperature. We report a maximum areal capacitance of 95 mF cm −2. Due to ∼40% increase in the penetrability coefficient of the ionic liquid, the electrode 'full' wetting time dropped from 48 to 5 h when the curing temperature was increased above 150 °C. These results were supported by SEM and Raman spectroscopy to characterise the effect of high temperature heat-treatment on the electrode-ionogel interface and the degree of electrode wetting by the ionic liquid. The fast-cure fabrication process for ionogels removes one of the major hurdles in their industrial application while the improved room temperature ion transport kinetics expands the potential application of ionic liquid-based electrochemical systems.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0378775318311583; http://dx.doi.org/10.1016/j.jpowsour.2018.10.049; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85055020224&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0378775318311583; https://dx.doi.org/10.1016/j.jpowsour.2018.10.049
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know