Evaluation of the temperature scale of SPRT calibrated at the triple point of sulfur hexafluoride
Measurement: Sensors, ISSN: 2665-9174, Vol: 18, Page: 100211
2021
- 1Citations
- 2Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
We evaluated the non-uniqueness of the temperature scale of the standard platinum resistance thermometer (SPRT) calibrated at the tripe point of sulfur hexafluoride (TPSF 6 ), which is one of the candidates for the substitute of the triple point of mercury (TPHg). Three SPRTs calibrated at the TPSF 6 were compared with a reference thermometer from 14 K to 250 K by using a precise comparison system for capsule type of thermometers. The uncertainty of the temperature scales from propagation of the uncertainties for calibrating SPRT was also evaluated. The result shows that the non-uniqueness of the temperature scale of the SPRT calibrated at the TPSF 6 was almost equivalent to that of the ITS-90. This means that the triple point of TPSF 6 possessed a capability for realization of the temperature scale which was equivalent to the ITS-90.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S2665917421001744; http://dx.doi.org/10.1016/j.measen.2021.100211; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85122684475&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S2665917421001744; https://dx.doi.org/10.1016/j.measen.2021.100211
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know