Temperature characteristics of Rb-N 2 single-beam magnetometer with different buffer gas pressures
Measurement, ISSN: 0263-2241, Vol: 215, Page: 112860
2023
- 5Citations
- 2Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
We demonstrate the temperature characteristics of Rb-N 2 single-beam spin-exchange relaxation-free (SERF) magnetometer with different buffer gas pressures. An optimization model is proposed to reveal that the optimal condition is determined by cell temperature and gas pressure simultaneously, where the magnetometer response is maximized. Three Rb-N 2 vapor cells under different gas pressures are constructed with interior volume of 3 × 3 × 3 mm 3, and a single-beam zero-field modulation magnetometer is carried out. For each individual vapor cell, the optical power density and cell temperature are optimized to obtain the maximum response signal. The unique optimal condition including cell temperature and gas pressure is determined with 1.55 amg at 148 ℃, which verifies the proposed optimization model. This study is significative for optimizing the miniature vapor cell parameters and contributes to further improving the performance of SERF magnetometer.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0263224123004244; http://dx.doi.org/10.1016/j.measurement.2023.112860; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85152241934&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0263224123004244; https://dx.doi.org/10.1016/j.measurement.2023.112860