Fringe-to-pulse counting demodulation of a laser interferometer for primary vibration calibration
Measurement, ISSN: 0263-2241, Vol: 221, Page: 113490
2023
- 1Citations
- 7Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
A high accuracy and real-time amplitude-phase demodulation method based on the pulse counting of optical fringes is proposed for a laser interferometer to realize amplitude and phase measurement of the vibration in primary vibration calibration. The two orthogonally analog signals with high frequency are converted into two digital signals through the comparison module instead of a high-speed data acquisition device. Then one displacement increment during a quarter period of the digital signal can be obtained by the high-frequency clock through comparing the four states of two orthogonally digital signals. The actual output rate of the demodulation data will be decreased by subsample with the vibration frequency. The results of experiment illustrated the deviations were within the limits and the displacement waves were well reconstructed, not only for homodyne interferometer but also for heterodyne interferometer. The proposed method involves less complicated hardware equipment and algorithm, so it is sufficient for real-time and high-precision demodulation of the laser interference signals to realize vibration measurements in primary vibration calibration.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0263224123010540; http://dx.doi.org/10.1016/j.measurement.2023.113490; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85169061003&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0263224123010540; https://dx.doi.org/10.1016/j.measurement.2023.113490
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know