Europium–organic complex as luminescent marker for the visual identification of gunshot residue and characterization by electrospray ionization FT-ICR mass spectrometry
Microchemical Journal, ISSN: 0026-265X, Vol: 116, Page: 216-224
2014
- 23Citations
- 44Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
A new high photoluminescent metal–organic complex is proposed as an optical marker for the indentification of gunshot residues (GSR) produced from firearms. The marker containing Eu 3+ ion was synthesized producing the [Eu(PIC) 3 (NMK) 3 ] complex, where PIC is picric acid and NMK is n -methyl caprolactam. It was chemically characterized using emission spectroscopy, Fourier transform infrared spectroscopy, thermogravimetric and differential thermal analyses, and electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FT-ICR MS) and then added to conventional ammunition as function of its concentration (from 2 to 50 mg by ammunition). Marked conventional GSR was visually and chemically detected by UV irradiation ( λ = 395 nm) and ESI-FT-ICR MS. The tests indicated that marked GSR is easily visible in proportions above of 25 mg on the target, bullets and firearms regions and on the arm of shooter. It was also detected at lower concentrations using ESI-FT-ICR MS. A final cost of the process is evaluated be lower than US$ 1.50/by ammunition, where 1 g of marker suffices to tag approximately 40.40 bullets.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0026265X1400085X; http://dx.doi.org/10.1016/j.microc.2014.05.009; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84901405005&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0026265X1400085X; https://dx.doi.org/10.1016/j.microc.2014.05.009
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know