New quantification approaches for total-reflection X-ray fluorescence analysis of micro-sized samples: Apatite case study
Microchemical Journal, ISSN: 0026-265X, Vol: 193, Page: 109139
2023
- 3Citations
- 1Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Sensitive methods for quantitative elemental analysis of micro-sized samples are limited. In this study, total-reflection X-ray fluorescence (TXRF) method was applied as fast and cost-efficient method to apatite microcrystals. In situ acid digestion based on direct treatment of single crystal onto the carrier was used as sample preparation strategy. Since the internal standard addition is complicated in the case of micro-sized samples, new quantification approaches based on external calibration for TXRF analysis of apatite were offered. An experimental design was created for apatite samples with a differentiation of specimen masses from 1.0 to 100 μg to find patterns in the spectral information. A workflow has been proposed for analyzing apatite crystals of various sizes (100, 500, 1000 µm) with TXRF based on an external calibration using an apatite powder sample as a standard and normalizing the spectra to the P-Kα and Mo-Kα peaks. The conditions of the workflow should be the following: Ca/P ratio is in a range between 19 and 23, and a dead time value does not exceed 4.0 %. The dead time value was used as a main factor of quantification, when calibration sample should match the unknown sample. Limit of detection values of the proposed method are from 1.0 to 100 μg/g depending on the crystal size and element of interest. Validation of the TXRF method was performed by analysis of Durango and McClure apatite samples. Comparison of TXRF results with laser ablation inductively coupled plasma mass spectrometry data showed the good agreement between two methods.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0026265X23007580; http://dx.doi.org/10.1016/j.microc.2023.109139; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85166323437&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0026265X23007580; https://dx.doi.org/10.1016/j.microc.2023.109139
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know