A low detection limit penicillin biosensor based on single graphene nanosheets preadsorbed with hematein/ionic liquids/penicillinase
Materials Science and Engineering: C, ISSN: 0928-4931, Vol: 39, Issue: 1, Page: 92-99
2014
- 47Citations
- 43Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations47
- Citation Indexes47
- 47
- CrossRef38
- Captures43
- Readers43
- 43
Article Description
In this study, we reported on a low detection limit penicillin biosensor with layer-by-layer (LbL) film containing single-graphene nanosheets (SGNs) preadsorbed with hematein, ionic liquids (ILs) and penicillinase. The penicillinase catalyzes the hydrolysis of penicillin to penicilloic acid, where H + is liberated and monitored amperometrically with hematein as a pH indicator. The SGN-hematein/ILs/penicillinase biosensor exhibited excellent performance for penicillin in PBS with a wide range from 1.25 × 10 −13 to 7.5 × 10 −3 M, and a low detection limit of 10 −13 M (0.04 ppt, S/N ≥ 3). Furthermore, the detection of penicillin concentration in real sample (milk) had acceptable accuracy with the assay system.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0928493114000873; http://dx.doi.org/10.1016/j.msec.2014.02.012; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84896132251&origin=inward; http://www.ncbi.nlm.nih.gov/pubmed/24863203; https://linkinghub.elsevier.com/retrieve/pii/S0928493114000873; https://dx.doi.org/10.1016/j.msec.2014.02.012
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know