Ultratrace determination of metal ions using graphene oxide/carbon nanotubes loaded cellulose membranes and total-reflection X-ray fluorescence spectrometry: A green chemistry approach
Spectrochimica Acta Part B: Atomic Spectroscopy, ISSN: 0584-8547, Vol: 177, Page: 106069
2021
- 9Citations
- 21Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
In this paper, the determination of ultratrace heavy metal ions was developed by combining a preconcentration method using graphene oxide/carbon nanotubes membranes (GO/CNTs) and total-reflection X-ray fluorescence spectrometry (TXRF). Due to the excellent adsorptive properties of the GO, the foregoing membranes are suitable for effective simultaneous sorption of Co(II), Ni(II), Cu(II), Zn(II), Cd(II), and Pb(II) from aqueous solutions. In this method, the aqueous solution is passed through the GO/CNTs membrane. The analytes are eluted from the GO and afterward transferred onto a siliconized quartz reflector for further TXRF analysis using W and Mo target X-ray tubes. The maximum recoveries for all the elements were obtained at pH 5; thus it was chosen for all further experiments. The face centered central composite design was performed to study the influence of the flow-rate and volume of the solution on the recovery of the determined metal ions. Recovery values higher than 96% for all studied metals allow performing efficient preconcentration with an enrichment factor of 133, achieving the limits of detection (LODs) in the range of 0.08–0.21 ng mL −1 for W target X-ray tube with a measurement time of 2000 s, and much lower LODs for Mo target X-ray tube: 0.001–0.002 ng mL −1 with the exception for Cd (0.11 ng mL −1 ) with a very short measurement time of 600 s. Certified reference materials of spring water and seawater were examined to verify the reliability of the method. The evaluated procedure does not require toxic reagents or organic solvents, thus minimizes the portion of the sample for TXRF measurement, and stands in good accordance with green analytical chemistry basic principles.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0584854721000057; http://dx.doi.org/10.1016/j.sab.2021.106069; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85100153076&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0584854721000057; https://dx.doi.org/10.1016/j.sab.2021.106069
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know