Taming the Pseudoelastic Response of Nitinol Using Ion Implantation
Scripta Materialia, ISSN: 1359-6462, Vol: 226, Page: 115261
2023
- 5Citations
- 9Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Implantation of Ni 50.5 Ti 49.5 wire with 30 MeV Ni 6+ ions at doses (< 0.1 DPA) typically smaller than employed in the literature is shown to systematically alter the pseudoelastic response, with extrema in Berkovich nanoindentation load (+50%), hysteresis (−60%), and recoverable displacement (−19%) occurring at ∼ 3.6 μm below the implantation surface. These extraordinary values are attributed to ∼ 10 to 20 nm amorphous clusters that constrain the stress-induced B2-B19′ phase transformation. This is substantiated by phase field simulations of crystalline-amorphous composites and molecular dynamics simulations of crystalline-vacancy cluster composites showing the spatial refinement of martensite caused by nm-scale defects. The results suggest that ion implantation may potentially expand the processing and performance space for NiTi, by creating amorphous defects at smaller length scales than dislocation substructures produced by conventional deformation processing.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S1359646222007552; http://dx.doi.org/10.1016/j.scriptamat.2022.115261; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85145966985&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S1359646222007552; https://dx.doi.org/10.1016/j.scriptamat.2022.115261
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know