Toward buildings with lower power demand in the smart city of NEOM-incorporating phase change material into building envelopes
Sustainable Energy Technologies and Assessments, ISSN: 2213-1388, Vol: 53, Page: 102494
2022
- 9Citations
- 26Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
The planning for Saudi Arabia's NEOM city, a smart city featuring tourism attractions, began in 2017 and the first phase will be operational by 2025. The employment of passive-based techniques to minimize energy consumption is one of the requirements of smart cities. In this study, the thermal behavior of three buildings in the presence of PCM is discussed. The first building has no PCM and has a wall thickness of 29 cm, but the second and third buildings have PCM and a wall thickness of 34 cm. In general, the installation of PCM in the northern, southern, eastern, and western walls is beneficial, as it reduced heat exchange by 63.5% in PCM-filled buildings compared to the reference one. The thickness of PCM is increased from 5 to 10 and 20 cm, and it is found that energy exchange in the second building is less than that in the first building by 4500, 7546 and 11,681 kWhyear at 5, 10, and 20 cm respectively. Although the increase in thickness is less effective for the third building, the amount of energy-saving is equal to 17120, 19835, and 21,215 kWhyear at 5, 10, and 20 cm.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S2213138822005446; http://dx.doi.org/10.1016/j.seta.2022.102494; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85134606004&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S2213138822005446; https://dx.doi.org/10.1016/j.seta.2022.102494
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know