Scanning optimization of an electrothermally-actuated MEMS mirror for applications in optical coherence tomography endoscopy
Sensors and Actuators A: Physical, ISSN: 0924-4247, Vol: 335, Page: 113377
2022
- 20Citations
- 8Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Probe is an important component of the optical coherence tomography (OCT) system. Electrothermally-actuated micro-electromechanical (MEMS) mirrors are especially suitable for OCT endoscopic imaging due to their large scan angle, low driving voltage and high fill factor. However, endoscopic OCT imaging quality would be seriously affected by the nonlinear scanning characteristics of electrothermal MEMS mirrors as well as the distortion due to the need of placing the MEMS mirror on a 45 ° slope. In this work, an open-loop control method based on the transfer function of the MEMS mirror is proposed to optimize the overall optical trajectory scanned on the sample under a MEMS OCT probe. The transfer function of the electrothermal MEMS mirror is established and the relation between the MEMS mirror’s tilt angle and the final scanning trajectory on the sample is calculated. A PID control model based on the transfer function is developed and employed to generate the driving voltage signals that can be applied to the MEMS mirror for obtaining undistorted scanning trajectories on the sample. Experiments show that the proposed method can correct the scanning nonlinearity and the distortion without adding extra hardware. For instance, the linear scanning ratio is improved from 72% up to 98%; the fan-shaped distortion is reduced by a factor 3–5. This method is also applied to a swept-source OCT system and the image distortions are compensated effectively.
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0924424722000152; http://dx.doi.org/10.1016/j.sna.2022.113377; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85123024855&origin=inward; https://linkinghub.elsevier.com/retrieve/pii/S0924424722000152; https://dx.doi.org/10.1016/j.sna.2022.113377
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know