Fluorescence detection for phosphate monitoring using reverse injection analysis
Talanta, ISSN: 0039-9140, Vol: 125, Page: 107-113
2014
- 46Citations
- 45Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations46
- Citation Indexes46
- 46
- CrossRef34
- Captures45
- Readers45
- 45
Article Description
We present a novel design for a compact flow-through fluorescence detector for flow analyses applications and prove its functionality in the experiment. The detector operates by detecting the diffusely emitted fluorescence in a glass capillary, which is a measure for the concentration of the analyte to be detected. The fluorescence is excited via an axially coupled fibre providing LED light and is collected by a photodiode. As model analyte we used dissolved reactive phosphate. The determination of the phosphate concentration is based on the reaction of molybdate to phosphomolybdate, which quenches the fluorescence of Rhodamine 6G. The experiments rely on a reversed flow injection analysis system especially designed for decoupling the analytical setup from environmental pressure for in situ applications. By combining the optics part and the fluidic setup a measuring range of 0–40 µg L −1 PO 4 –P with detection limits of 0.22 µg L −1 PO 4 –P (7 nmol L −1 ) for water and of 0.45 µg L −1 PO 4 –P (14.5 nmol L −1 ) for seawater have been obtained. Our novel system has a sampling frequency of up to 300 samples per hour and achieves a repeatability between 0.6% (RSD) for the blank value signal ( n =15) and 4.6% (RSD) for a phosphate concentration of 20.8 µg L −1 PO 4 –P ( n =15).
Bibliographic Details
http://www.sciencedirect.com/science/article/pii/S0039914014001702; http://dx.doi.org/10.1016/j.talanta.2014.02.072; http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84897086373&origin=inward; http://www.ncbi.nlm.nih.gov/pubmed/24840422; https://linkinghub.elsevier.com/retrieve/pii/S0039914014001702; https://dx.doi.org/10.1016/j.talanta.2014.02.072
Elsevier BV
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know