Development of a flow amperometric enzymatic method for the determination of total glucosinolates in real samples
Analytical Chemistry, ISSN: 0003-2700, Vol: 75, Issue: 4, Page: 927-934
2003
- 14Citations
- 9Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations14
- Citation Indexes14
- CrossRef14
- 14
- Captures9
- Readers9
Article Description
The first amperometric flow analyzer, based on the biosensor concept, capable of determining total glucosinolates in real samples, is described. Myrosinase was immobilized on aminopropyl-modified controlled pore glass, which was then used for the construction of a packed-bed reactor. Myrosinase catalyzes the hydrolysis of glucosinolates (sinigrin) to glucose (among the other products), which is then oxidized by the action of glucose oxidase to produce hydrogen peroxide. The glucose enzyme electrode is based on a multimembrane architecture and was mounted on an amperometric flow cell (hydrogen peroxide detection at a platinum anode poised at +0.65 V vs Ag/AgCl/3M KCl). Different membrane types and different activation procedures were tested. The system was optimized to various working parameters, either as a glucose electrode or as a glucosinolate analyzer. The interference effect of various compounds was also investigated. Application of the method to real samples was carried out using glucose/glucose, hydrolyzed sinigrin and glucose/sinigrin solution as calibrators of the glucose electrode and the glucosinolate analyzer. Deviations due to the enantioselectivity of glucose oxidase to the β-glucose anomer were observed, and a data elaboration protocol is proposed. The possibility of the simultaneous determination of glucose and glucosinolates is also demonstrated.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know