X-ray photoelectron spectroscopy, time-of-flight secondary ion mass spectrometry, and principal component analysis of the hydrolysis, regeneration, and reactivity of N-hydroxysuccinimide-containing organic thin films
Analytical Chemistry, ISSN: 0003-2700, Vol: 79, Issue: 22, Page: 8781-8788
2007
- 43Citations
- 55Captures
- 1Mentions
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations43
- Citation Indexes43
- 43
- CrossRef39
- Captures55
- Readers55
- 55
- Mentions1
- News Mentions1
- 1
Most Recent News
Biomedical surface analysis: Evolution and future directions (Review)
II. CASE STUDIES IN BIOMEDICAL SURFACE ANALYSIS A. Characterization of surface bound proteins One of the first events that occurs once a biomedical device is
Article Description
N-Hydroxysuccinimide (NHS) esters are widely used as leaving groups to activate covalent coupling of amine-containing biomolecules onto surfaces in academic and commercial surface immobilizations. Their intrinsic hydrolytic instability is well-known and remains a concern for maintaining stable, reactive surface chemistry, especially for reliable longer term storage. In this work, we use X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry (TOF-SIMS) to investigate surface hydrolysis in NHS-bearing organic thin films. Principal component analysis (PCA) of both positive and negative ion TOF-SIMS data was used to correlate changes in the well-defined NHS ester oligo(ethylene glycol) (NHS-OEG) self-assembled monolayers to their surface treatment. From PCA results, multivariate peak intensity ratios were developed for monitoring NHS reactivity, thin-film thickness, and oxidation of the monolayers during surface hydrolysis. Aging in ambient air for up to 7 days resulted in hydrolysis of some fraction of bound NHS groups, oxidation of some resident thiol groups, and deposition of adventitious hydrocarbon contaminants onto the monolayers. Overnight film immersion under water produced complete hydrolysis and removal of the NHS chemistry, as well as removal of some of the thiolated OEG chains. NHS regeneration of the hydrolyzed surfaces was assessed using the same multivariable peak intensity ratio as well as surface coupling with amine-terminated molecules. Both aqueous and organic NHS regeneration methods produced surfaces with bound NHS concentrations ∼50% of the bound NHS concentration on freshly prepared NHS-OEG monolayers. Precise methods for quantifying NHS chemistry on surfaces are useful for quality control processes required in surface technologies that rely on reliable and reproducible reactive ester coupling. These applications include microarray, microfluidic, immunoassay, bioreactor, tissue engineering, and biomedical device fabrication. © 2007 American Chemical Society.