Microdevice for on-site fish freshness checking based on K-value measurement
Analytical Chemistry, ISSN: 0003-2700, Vol: 85, Issue: 22, Page: 10962-10968
2013
- 40Citations
- 42Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations40
- Citation Indexes40
- 40
- CrossRef34
- Captures42
- Readers42
- 42
Article Description
An electrochemical microfluidic device with two sensing sites in the upper and lower streams of a flow channel was fabricated to measure the K-value as a means of evaluating the freshness of fish. In this device, plugs of solutions were processed using mechanisms to place a plug at the sensing site and to merge and mix two plugs in a single flow channel. The sums of ATP-related compound concentrations used for the calculation of the K-value were measured at the first and second sensing sites. The ratio of the output currents agreed well with the K-value calculated from predetermined concentrations in standard solutions. The K-values of jack mackerel, yellow tail, and sea bream extracts were then obtained using the device and were found to agree well with those obtained by high-performance liquid chromatography (HPLC). In addition, the changes in the K-value with time were observed to depend strongly on the type of fish for these three fish extracts. © 2013 American Chemical Society.