Robust Covalent Coupling Scheme for the Development of FRET Aptasensor based on Amino-Silane-Modified Graphene Oxide
Langmuir, ISSN: 1520-5827, Vol: 34, Issue: 48, Page: 14586-14596
2018
- 4Citations
- 15Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
In recent years, numerous aptamers have been physisorbed on graphene oxide (GO) to develop fluorescence resonance energy transfer-based aptasensors using the fluorescence quenching property of GO. However, physisorbed aptasensors show poor signal reversibility and reproducibility as well as nonspecific probe displacement, and thereby are not suitable for many analytical applications. To overcome these problems when working with complex biological samples, we developed a facile and robust covalent surface functionalization technique for GO-based fluorescent aptasensors using a well-studied adenosine triphosphate binding aptamer (ABA). In the scheme, GO is first modified with amino-silane, and further with glutaraldehyde to create available carbonyl groups for the covalent attachment of a fluorophore and an amino dual modified ABA. The surface modification method was characterized by ζ-potential, X-ray photoelectron spectroscopy, and Fourier-transform infrared spectroscopy (FTIR). The linearity, sensitivity, selectivity, and reversibility of the resulting GO-based covalent aptasensor was determined and systematically compared with the physisorbed aptasensor. Although both sensors showed similar performance in terms of sensitivity and linearity, better selectivity and higher resistance to nonspecific probe displacement was achieved with the developed covalent ABA sensor. The surface modification technique developed here is independent of the aptamer sequence, and therefore could be used universally for different analytical applications simply by changing the aptamer sequence for the target biomolecule.
Bibliographic Details
American Chemical Society (ACS)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know