Robust and Highly Sensitive Cellulose Nanofiber-Based Humidity Actuators
ACS Applied Materials and Interfaces, ISSN: 1944-8252, Vol: 13, Issue: 45, Page: 54417-54427
2021
- 52Citations
- 28Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations52
- Citation Indexes52
- 52
- CrossRef11
- Captures28
- Readers28
- 28
Article Description
The design of humidity actuators with high response sensitivity (especially actuation time) while maintaining favorable mechanical properties is important for advanced intelligent manufacturing, like soft robotics and smart devices, but still remains a challenge. Here, we fabricate a robust and conductive composite film-based humidity actuator with synergetic benefits from one-dimensional cellulose nanofibers (CNFs) and carbon nanotubes (CNTs) as well as two-dimensional graphene oxide (GO) via an efficient vacuum-assisted self-assembly method. Owing to the excellent moisture sensitivity of CNF and GO, the hydrophobic CNT favoring rapid desorption of water molecules, and the unique porous structure with numerous nanochannels for accelerating the water exchange rate, this CNF/GO/CNT composite film delivers excellent actuation including an ultrafast response/recovery (0.8/2 s), large deformation, and sufficient cycle stability (no detectable degradation after 1000 cycles) in response to ambient gradient humidity. Intriguingly, the actuator could also achieve a superior flexibility, a good mechanical strength (201 MPa), a desirable toughness (6.6 MJ/m3), and stable electrical conductivity. Taking advantage of these benefits, the actuator is conceptually fabricated into various smart devices including mechanical grippers, crawling robotics, and humidity control switches, which is expected to hold great promise toward practical applications.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know