Pyrene Excimer-Based Peptidyl Chemosensors for the Sensitive Detection of Low Levels of Heparin in 100% Aqueous Solutions and Serum Samples
ACS Applied Materials and Interfaces, ISSN: 1944-8252, Vol: 7, Issue: 26, Page: 14243-14253
2015
- 72Citations
- 22Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations72
- Citation Indexes72
- 72
- CrossRef60
- Captures22
- Readers22
- 22
Article Description
Fluorescent chemosensors (1 and 2, Py-(Arg)nGlyGlyGly(Arg)nLys(Py)-NH2, n = 2 and 3) bearing two pyrene (Py) labeled heparin-binding peptides were synthesized for the sensitive ratiometric detection of heparin. The peptidyl chemosensors (1 and 2) sensitively detected nanomolar concentrations of heparin in aqueous solutions and in serum samples via a ratiometric response. In 100% aqueous solutions at pH 7.4, both chemosensors exhibited significant excimer emission at 486 nm as well as weak monomer emission in the absence of heparin. Upon the addition of heparin into the solution, excimer emission increased with a blue shift (10 nm) and monomer emission at 376 nm decreased. The chemosensors showed a similar sensitive ratiometric response to heparin independent of the concentration of the chemosensors. The peptidyl chemosensors were applied to the ratiometric detection of heparin over a wide range of pH (1.5-11.5) using the excimer/momomer emission changes. In the presence of serum, 1 and 2 displayed significant monomer emission at 376 nm with relatively weak excimer emission and the addition of heparin induced a significant increase in excimer emission at 480 nm and a concomitant decrease in monomer emission. The enhanced ratiometric response to heparin in the serum sample was due to the interactions between the peptidyl chemosensors and serum albumin in the serum sample. The detection limits of 2 for heparin were less than 1 nM in 100% aqueous solutions and serum samples. The peptidyl chemosensors bearing two heparin-binding sites are a suitable tool for the sensitive ratiometric detection of nanomolar concentrations of heparin in 100% aqueous solutions and serum samples.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know