Effect of monochloramine treatment on colonization of a hospital water distribution system by legionella spp.: A 1 year experience study
Environmental Science and Technology, ISSN: 1520-5851, Vol: 49, Issue: 7, Page: 4551-4558
2015
- 12Citations
- 34Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations12
- Citation Indexes11
- 11
- CrossRef7
- Policy Citations1
- Policy Citation1
- Captures34
- Readers34
- 34
Article Description
Contamination of hot water distribution systems by Legionella represents a great challenge due to difficulties associated with inactivating microorganisms, preserving the water characteristics. The aim of this study was to examine over the course of 1 year in 11 fixed sites, the impact of monochloramine disinfection on Legionella, heterotrophic bacteria (36°C), Pseudomonas aeruginosa contamination, and chemical parameters of a plumbing system in an Italian hospital. Three days after installation (T0), in the presence of monochloramine concentration between 1.5 and 2 mg/L, 10/11 sites (91%) were contaminated by L. pneumophila serogroups 3 and 10. After these results, the disinfectant dosage was increased to between 6 and 10 mg/L, reducing the level of Legionella by three logarithmic unit by 2 months postinstallation (T2) until 6 months later (T3). One year later (T4), there was a significant reduction (p = 0.0002) at 8/11 (73%) sites. Our data showed also a significant reduction of heterotrophic bacteria (36°C) in 6/11 (55%) sites at T4 (p = 0.0004), by contrast the contamination of P. aeruginosa found at T0 in two sites persisted up until T4. The results of the present study show that monochloramine is a promising disinfectant that can prevent Legionella contamination of hospital water supplies.