Detection of NO down to ppb levels using individual and multiple InO nanowire devices
Nano Letters, ISSN: 1530-6984, Vol: 4, Issue: 10, Page: 1919-1924
2004
- 864Citations
- 329Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
We demonstrate detection of NO down to ppb levels using transistors based on both single and multiple InO nanowires operating at room temperature. This represents orders-of-magnitude improvement over previously reported metal oxide film or nanowire/nanobelt sensors. A comparison between the single and multiple nanowire sensors reveals that the latter have numerous advantages in terms of great reliability, high sensitivity, and simplicity in fabrication. Furthermore, selective detection of NO can be readily achieved with multiple-nanowire sensors even with other common chemicals such as NH, O, CO, and H around.
Bibliographic Details
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know