PlumX Metrics
Embed PlumX Metrics

Free-space dissemination of time and frequency with 10 instability over 113 km

Nature, ISSN: 1476-4687, Vol: 610, Issue: 7933, Page: 661-666
2022
  • 75
    Citations
  • 0
    Usage
  • 59
    Captures
  • 4
    Mentions
  • 0
    Social Media
Metric Options:   Counts1 Year3 Year

Metrics Details

Most Recent Blog

From “Eos” : "Precisely Synced Clocks Pave the Way for New Science"

From “Eos” AT AGU 8.4.23 Katherine Kornei Researchers working on Hawai'ian mountain tops precisely synchronized two clocks with unprecedented efficiency, demonstrating the potential to create

Most Recent News

Precisely Synced Clocks Pave the Way for New Science

From the pendulum clocks of the 17th century to cutting-edge chronometers based on atomic transitions, humans’ ability to mark time has evolved dramatically. Researchers have now gone one step further and shown that two clocks can be exquisitely synchronized over a distance of several hundred kilometers using significantly less power than previously required. This advance paves the way for creatin

Article Description

Networks of optical clocks find applications in precise navigation, in efforts to redefine the fundamental unit of the ‘second’ and in gravitational tests. As the frequency instability for state-of-the-art optical clocks has reached the 10 level, the vision of a global-scale optical network that achieves comparable performances requires the dissemination of time and frequency over a long-distance free-space link with a similar instability of 10. However, previous attempts at free-space dissemination of time and frequency at high precision did not extend beyond dozens of kilometres. Here we report time–frequency dissemination with an offset of 6.3 × 10 ± 3.4 × 10 and an instability of less than 4 × 10 at 10,000 s through a free-space link of 113 km. Key technologies essential to this achievement include the deployment of high-power frequency combs, high-stability and high-efficiency optical transceiver systems and efficient linear optical sampling. We observe that the stability we have reached is retained for channel losses up to 89 dB. The technique we report can not only be directly used in ground-based applications, but could also lay the groundwork for future satellite time–frequency dissemination.

Bibliographic Details

Shen, Qi; Guan, Jian-Yu; Ren, Ji-Gang; Zeng, Ting; Hou, Lei; Li, Min; Cao, Yuan; Han, Jin-Jian; Lian, Meng-Zhe; Chen, Yan-Wei; Peng, Xin-Xin; Wang, Shao-Mao; Zhu, Dan-Yang; Shi, Xi-Ping; Wang, Zheng-Guo; Li, Ye; Liu, Wei-Yue; Pan, Ge-Sheng; Wang, Yong; Li, Zhao-Hui; Wu, Jin-Cai; Zhang, Yan-Yan; Chen, Fa-Xi; Lu, Chao-Yang; Liao, Sheng-Kai; Yin, Juan; Jia, Jian-Jun; Peng, Cheng-Zhi; Jiang, Hai-Feng; Zhang, Qiang; Pan, Jian-Wei

Springer Science and Business Media LLC

Multidisciplinary

Provide Feedback

Have ideas for a new metric? Would you like to see something else here?Let us know