Reproducibility of CIGS thin film analysis by laser-induced breakdown spectroscopy
Journal of Analytical Atomic Spectrometry, ISSN: 0267-9477, Vol: 28, Issue: 4, Page: 473-481
2013
- 21Citations
- 11Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
The reproducibility of an elemental analysis of thin CIGS solar cell films by laser-induced breakdown spectroscopy (LIBS) is assessed. A Q-switched Nd:YAG laser (λ = 532 nm, τ = 5 ns, top-hat profile) and an ICCD detector were used for the LIBS measurements. It was shown that the concentration ratios and depth profile of a CIGS sample with unknown composition could be predicted with high precision by using the calibration curves generated with reference CIGS samples. The spot-to-spot relative standard deviation of 1.4% could be achieved for (Ga + In)/Cu at the gate delay of 0.1 μs condition, demonstrating that LIBS can be applied for real time monitoring of the elemental composition of CIGS thin films.© The Royal Society of Chemistry 2013.
Bibliographic Details
Royal Society of Chemistry (RSC)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know