Determination of micro and macro elements in iron supplements used for treatment of anemia and evaluation employing chemometric analysis tools
RSC Advances, ISSN: 2046-2069, Vol: 5, Issue: 67, Page: 54046-54052
2015
- 7Citations
- 6Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
This paper propose a method using inductively coupled plasma optical emission spectrometry (ICP OES) for the determination of Ca, K, Mg, Mn, Na, P and Zn in iron supplement used for the treatment of anemia and evaluation of the results by chemometric analysis tools, principal component analysis (PCA) and hierarchical cluster analysis (HCA). Sample preparation was performed by acid digestion using 3.0 mL of HNO3 and 1.0 mL of H2O2 (30% v/v). Limits of quantification (mg L-1) were 0.52 for Ca, 0.14 for K, 0.03 for Mg, 0.07 for Mn, 0.40 for Na, 0.36 for P and 0.24 for Zn, showing that the method is sensitive for the determination of elements. There is no certified reference material of ferrous supplement for evaluation of the accuracy. Thus, addition/recovery tests were performed to evaluate the accuracy of the method. The recovery values achieved varied from 89.75 to 114.97%, confirming the applicability of this method for quantification of the mentioned elements in these iron supplements. The method proposed was applied for determination of Ca, K, Mg, Mn, Na, P and Zn in seventeen iron supplement samples with different chemical composition. All results were evaluated by multivariate analysis tools, which have the ability to characterize the samples by chemical composition and the analyte content. Some samples showed higher values for some metals, indicating the importance of specific legislation also for these metals.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84934996205&origin=inward; http://dx.doi.org/10.1039/c5ra03242c; https://xlink.rsc.org/?DOI=C5RA03242C; http://xlink.rsc.org/?DOI=C5RA03242C; http://pubs.rsc.org/en/content/articlepdf/2015/RA/C5RA03242C; https://dx.doi.org/10.1039/c5ra03242c; https://pubs.rsc.org/en/content/articlelanding/2015/ra/c5ra03242c
Royal Society of Chemistry (RSC)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know