Determination of scandium in monazite and environmental samples using cloud point extraction coupled with a spectrophotometric technique
RSC Advances, ISSN: 2046-2069, Vol: 6, Issue: 77, Page: 73797-73804
2016
- 4Citations
- 8Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
A method for the determination of scandium in monazite and environmental samples at trace levels is presented. The Sc(iii) complex is preconcentrated using the cloud point extraction process with the nonionic surfactant Triton X-100 to extract the Sc(iii) complex from aqueous solutions of pH 5.5. Sc(iii) ions were complexed with 2-amino-4-(m-tolyazo)pyridine-3-ol (ATAP) as a complexing agent in aqueous medium and concentrated by Triton X-100 as surfactant. After the phase separation at 45 °C based on the cloud point extraction of the mixture, the surfactant-rich phase was dried and the remaining phase was dissolved with 0.5 mL of dimethylformamide. Under the optimum conditions, the calibration curve is linear for the concentration range of 0.4-65 ng mL and the detection limit was 0.12 ng mL. The enhancement factor of 500 was achieved for 250 mL samples containing the analyte with RSDs ≥1.10%. The method is highly selective, fairly sensitive, simple, rapid, economical and safely applied to determine Sc(iii) ions in different complex materials, such as monazite and environmental samples.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84981332660&origin=inward; http://dx.doi.org/10.1039/c6ra10049j; https://xlink.rsc.org/?DOI=C6RA10049J; http://xlink.rsc.org/?DOI=C6RA10049J; http://pubs.rsc.org/en/content/articlepdf/2016/RA/C6RA10049J; https://dx.doi.org/10.1039/c6ra10049j; https://pubs.rsc.org/en/content/articlelanding/2016/ra/c6ra10049j
Royal Society of Chemistry (RSC)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know