A capacitive DNA sensor for sensitive detection of: Escherichia coli O157:H7 in potable water based on the z3276 genetic marker: Fabrication and analytical performance
Analyst, ISSN: 1364-5528, Vol: 145, Issue: 6, Page: 2267-2278
2020
- 25Citations
- 26Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations25
- Citation Indexes25
- CrossRef25
- 24
- Captures26
- Readers26
- 26
Article Description
We report a label-free biosensor for the detection of Escherichia coli O157:H7 ATCC 43895 in potable water using a newly designed DNA sensing probe targeting the z3276 genetic marker. The surface of indium tin oxide (ITO) was functionalized with the novel sensing probe by covalent coupling using APTES as a crosslinker to fabricate the DNA sensor (dubbed ZEC [z3276 gene of E. coli O157:H7 ATCC 43895]). The electrochemical characterization of the fabricated ZEC sensor was performed using cyclic voltammetry and electrochemical impedance spectroscopy. Atomic force microscopy and scanning electron microscopy revealed significant changes in the surface topographies of the fabricated ZEC sensor chip. Equivalent circuit analyses suggested the capacitive nature of the ZEC sensor chip, which demonstrated a declining trend of the capacitance value from 1.568 μF (Bare ITO) to 1.221 μF (after DNA hybridization). Non-faradaic sensing measurements revealed systematically declining capacitance values upon DNA hybridization, with a 10 min response time at 10 Hz frequency and 10 mV applied potential. The ZEC sensor chip exhibited linearity in the range of 0.5 to 25 pg per 10 mL for E. coli O157:H7, with ubiquitous cross-validation of each DNA concentration using quantitative PCR prior to the analyses of real water samples. The limit of detection (LOD) at 95% confidence estimated by logistic regression was 0.1 pg DNA per 10 mL of E. coli O157:H7 (equivalent to 13.67 CFU per 10 mL) with a p-value of 0.0237. Consequently, the obtained results demonstrate the possible application of the developed ZEC sensor chip for E. coli O157:H7 detection in real water samples.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85081919281&origin=inward; http://dx.doi.org/10.1039/c9an02291k; http://www.ncbi.nlm.nih.gov/pubmed/31996887; https://xlink.rsc.org/?DOI=C9AN02291K; https://dx.doi.org/10.1039/c9an02291k; https://pubs.rsc.org/en/content/articlelanding/2020/an/c9an02291k
Royal Society of Chemistry (RSC)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know