Measurement of the magnetic susceptibility of subtle paramagnetic solutions using the diamagnetic repulsion of polymer microparticles
Lab on a Chip, ISSN: 1473-0189, Vol: 19, Issue: 14, Page: 2356-2361
2019
- 10Citations
- 16Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations10
- Citation Indexes10
- 10
- CrossRef8
- Captures16
- Readers16
- 16
Article Description
Herein, we described a microfluidic device that enabled the measurement of magnetic susceptibility of a subtle paramagnetic solution that could not be determined by conventional magnetic susceptibility measurement methods such as a superconducting quantum interference device (SQUID). We measured the diamagnetic repelling velocity of polystyrene microparticles suspended in a weak paramagnetic solution including 50-150 mM of gadolinium-diethylenetriamine penta-acetic acid (GD-DTPA) and superparamagnetic iron oxide nanoparticles (SPION) (10 nm in diameter) dispersed in distilled water at various concentrations. The measured diamagnetic repelling velocities correlated with our prediction and also with the magnetic susceptibility of the SPION solution measured by a SQUID magnetometer. Via this approach, we could determine the magnetic susceptibility of the subtle paramagnetic solution of GD-DTPA that could not be measured via the conventional method. This study provides us with the new capability of analyzing weakly paramagnetic solutions such as paramagnetic components or metal contaminants present in environmental liquid samples at low concentrations.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85068785220&origin=inward; http://dx.doi.org/10.1039/c9lc00245f; http://www.ncbi.nlm.nih.gov/pubmed/31173624; https://xlink.rsc.org/?DOI=C9LC00245F; https://dx.doi.org/10.1039/c9lc00245f; https://pubs.rsc.org/en/content/articlelanding/2019/lc/c9lc00245f