A new approach for baseline correction in laser induced breakdown spectroscopy
Journal of Analytical Atomic Spectrometry, ISSN: 1364-5544, Vol: 37, Issue: 5, Page: 1134-1140
2022
- 8Citations
- 9Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
Laser-induced breakdown spectroscopy is a promising technique in ocean applications due to its great capability of in situ detection. However, LIBS detection is not satisfactory in water, and a typical performance is that emission lines usually overlap with the high spectral background. So, it is necessary to correct the baseline (i.e. spectral background) in signal processing to obtain better signals for quantitative or qualitative analysis. In this work, we developed a new method (WASS: wavelength artificial shift subtraction) to remove the spectral background for underwater detection of LIBS. The method is easy to conduct by making a wavelength shift on a single spectrum. After conducting a subtraction between shifted- and unshifted spectra, the high baseline of the LIBS signal could be well corrected, especially for weak signals. Moreover, signal fluctuation was significantly decreased, and a fine quantitative analysis could be established with a low standard deviation. The obtained results suggested that the method was effective in baseline correction for signal extraction, and it might be a practical way for LIBS quantitation in the future.
Bibliographic Details
Royal Society of Chemistry (RSC)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know