Amphiphilic silicones to mitigate lens epithelial cell growth on intraocular lenses
Journal of Materials Chemistry B, ISSN: 2050-7518, Vol: 10, Issue: 16, Page: 3064-3072
2022
- 3Citations
- 3Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations3
- Citation Indexes3
- CrossRef3
- Captures3
- Readers3
Article Description
Silicone intraocular lenses (IOLs) that resist lens epithelial cell (LEC) growth would greatly improve patient outcomes. Herein, amphiphilic surface modifying additives (SMAs) were incorporated into an IOL-type diphenyl silicone to reduce LEC growth without compromising opto-mechanical properties. The SMAs were poly(ethylene oxide)-silane amphiphiles (PEO-SAs) [H-Si-ODMS-block-PEO-OCH], comprised of a PEO segment and siloxane tether of varying lengths (m = 0, 13, and 30). These three SMAs were each blended into the addition cure diphenyl silicone at varying concentrations (5, 10, 15, 20, and 25 μmol g) wherein the wt% of PEO was maintained for all SMAs at a given molar concentration. The chemical crosslinking and subsequent retention of SMAs in modified silicones was confirmed. Key material properties were assessed following equilibration in both air and aqueous environments. Silicones modified with SMAs having longer tethers (m = 13 and 30) underwent rapid and substantial water-driven restructuring of PEO to the surface to form highly hydrophilic surfaces, especially as SMA concentration increased. The % transmittance was also maintained for silicones modified with these particular SMAs. The moduli of the modified silicones were largely unchanged by the SMA and remained in the typical range for silicone IOLs. When the three SMAs were introduced at the highest concentration, modified silicones remained non-cytotoxic and LEC count and associated alpha-smooth muscle actin (α-SMA) expression decreased with increasing tether length. These results demonstrate the potential of silicones modified with PEO-SA SMAs to produce LEC-resistant IOLs.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85127856905&origin=inward; http://dx.doi.org/10.1039/d2tb00213b; http://www.ncbi.nlm.nih.gov/pubmed/35332909; https://xlink.rsc.org/?DOI=D2TB00213B; https://dx.doi.org/10.1039/d2tb00213b; https://pubs.rsc.org/en/content/articlelanding/2022/tb/d2tb00213b
Royal Society of Chemistry (RSC)
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know