Minimally Invasive Aortic Valve Replacement in Contemporary Practice: Clinical and Hemodynamic Performance from a Prospective Multicenter Trial
Thoracic and Cardiovascular Surgeon, ISSN: 1439-1902, Vol: 71, Issue: 5, Page: 387-397
2021
- 3Citations
- 3Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Citations3
- Citation Indexes3
- Captures3
- Readers3
Conference Paper Description
Background The advent of transcatheter aortic valve replacement (AVR) has led to an increased emphasis on reducing the invasiveness of surgical procedures. The aim of this study was to evaluate clinical outcomes and hemodynamic performance achieved with minimally invasive aortic valve replacement (MI-AVR) as compared with conventional AVR. Methods Patients who underwent surgical AVR with the Avalus bioprosthesis, as part of a prospective multicenter non-randomized trial, were included in this analysis. Surgical approach was left to the discretion of the surgeons. Patient characteristics and clinical outcomes were compared between MI-AVR and conventional AVR groups in the entire cohort (n = 1077) and in an isolated AVR subcohort (n = 528). Propensity score adjustment was performed to estimate the effect of MI-AVR on adverse events. Results Patients treated with MI-AVR were younger, had lower STS scores, and underwent concomitant procedures less often. Valve size implanted was comparable between the groups. MI-AVR was associated with longer procedural times in the isolated AVR subcohort. Postprocedural hemodynamic performance was comparable. There were no significant differences between MI-AVR and conventional AVR in early and 3-year all-cause mortality, thromboembolism, reintervention, or a composite of those endpoints within either the entire cohort or the isolated AVR subcohort. After propensity score adjustment, there remained no association between MI-AVR and the composite endpoint (hazard ratio: 0.86, 95% confidence interval: 0.47-1.55, p = 0.61). Conclusion Three-year outcomes after MI-AVR with the Avalus bioprosthetic valve were comparable to conventional AVR. These results provide important insights into the overall ability to reduce the invasiveness of AVR without compromising outcomes.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85167481542&origin=inward; http://dx.doi.org/10.1055/s-0042-1743593; http://www.ncbi.nlm.nih.gov/pubmed/35644134; http://www.thieme-connect.de/DOI/DOI?10.1055/s-0042-1743593; https://dx.doi.org/10.1055/s-0042-1743593; https://www.thieme-connect.de/products/ejournals/abstract/10.1055/s-0042-1743593
Georg Thieme Verlag KG
Provide Feedback
Have ideas for a new metric? Would you like to see something else here?Let us know