Flexural Test on a Full-Scale 60-kW Wind Turbine-Tower Telescopic Steel Pipe
Practice Periodical on Structural Design and Construction, ISSN: 1084-0680, Vol: 24, Issue: 3
2019
- 2Citations
- 8Captures
Metric Options: CountsSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Article Description
A full-scale static test to failure was conducted on 6-m (236.22 in.)-long steel pipes constituting a segment of a telescopic wind tower with a 60-kW wind turbine. The diameter of the circular cross section of the steel pipes was 900 mm (35.43 in.), and the nominal thickness was 10 mm (0.39 in.). The steel grade was 355 MPa (51,488 psi). The tests were conducted in a force-controlled mode in a four-point bending test with a shear-to-span ratio of 2.05. The flexural limit states developed in the form of ovalization of the cross section and of local buckling. The buckling occurred in the plastic range because of the diameter-to-thickness ratio of the section. Although local buckling caused slight strength degradation, the reduction due to the shear-to-moment interaction and ovalization of the cross section was very significant (58%), while the recorded response revealed a good amount of postbuckling ductility (2.42). A finite-element analysis with ABAQUS code was also conducted for comparison with the experimental results and for validation of the simplified proposed model. By properly modeling the imperfection effects due to the roundness of the steel tube, good correlation of the structural response and failure mode, and with the analytical model, were also achieved.
Bibliographic Details
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85065318463&origin=inward; http://dx.doi.org/10.1061/(asce)sc.1943-5576.0000433; https://ascelibrary.org/doi/10.1061/%28ASCE%29SC.1943-5576.0000433; http://dx.doi.org/10.1061/%28asce%29sc.1943-5576.0000433; https://dx.doi.org/10.1061/%28asce%29sc.1943-5576.0000433