Tritium depth dependence of tritium imaging
Review of Scientific Instruments, ISSN: 0034-6748, Vol: 72, Issue: 6, Page: 2593-2598
2001
- 2Captures
Metric Options: Counts1 Year3 YearSelecting the 1-year or 3-year option will change the metrics count to percentiles, illustrating how an article or review compares to other articles or reviews within the selected time period in the same journal. Selecting the 1-year option compares the metrics against other articles/reviews that were also published in the same calendar year. Selecting the 3-year option compares the metrics against other articles/reviews that were also published in the same calendar year plus the two years prior.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Example: if you select the 1-year option for an article published in 2019 and a metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019. If you select the 3-year option for the same article published in 2019 and the metric category shows 90%, that means that the article or review is performing better than 90% of the other articles/reviews published in that journal in 2019, 2018 and 2017.
Citation Benchmarking is provided by Scopus and SciVal and is different from the metrics context provided by PlumX Metrics.
Metrics Details
- Captures2
- Readers2
Article Description
A Monte Carlo simulation of tritium β particle motion in a matrix material indicates that the probability of escape through the material surface is greater than 50% for near-surface tritium, but drops quite rapidly with increasing depth. Beyond an areal density depth of 2 × 10 g/cm, the decline is close to exponential, with an e-folding length of approximately 3 × 10 g/cm, the exact value varying slightly with the material. The sensitivity of the tritium imaging technique will decrease at a similar rate with increasing depth of tritium. Experimentally, the image intensity of a tritium-implanted graphite specimen was observed to decrease exponentially with coating thickness as an aluminum layer was evaporated onto its surface, with an exponent that was within 30% of the predicted value. The Monte Carlo simulation also indicated that the limit of lateral resolution of the tritium imaging technique will be slightly less than the depth of the tritium, subject always to Recknagel's limit of resolution due to "chromatic aberration" of the electron optics, which is of the order of 200 nm. If tritium is uniformly distributed through the material, surface tritium so dominates image formation that Recknagel's limit inevitably applies. © 2001 American Institute of Physics.